The system is designed for July and then tested in January — usually once a decade, and badly.
The reference station records a July mean of 84.8°F and a January mean of 52.2°F, and those two numbers describe the design problem exactly: a cooling season that runs most of the year and a heating season that is short, mild — and occasionally interrupted by a hard freeze that the housing stock is not built for. Two-thirds of the housing is single-family detached and a third predates 1980, so the typical job is a system in an attic serving a house whose ducts and insulation were specified for a different era of energy costs.
Gulf moisture arrives with the summer air, so the load is not only temperature. A system that is oversized will reach the set point quickly and shut off before it has removed much moisture, which produces a house that feels clammy at 74°F. A load calculation that treats latent load as a design condition — and equipment that can run longer at reduced capacity — is the answer. Ask whether the calculation was done room by room, whether it accounts for humidity, and what the airflow setting will be.
Attic air handlers and flex duct are standard here, and in a metro where the attic is hot for months, every unsealed plenum, boot and cabinet is a capacity leak. It is not unusual for a system to be correctly sized and still fail to cool the far end of the house because the distribution is losing more than the equipment is adding. Ask whether the ducts will be tested or inspected, what insulation value is specified, and whether the plenum and boots will be sealed as part of the work.
The heating side is neglected because it is needed so rarely, and that is exactly when it fails. A heat pump that has not been checked may run in defrost constantly, auxiliary heat may be undersized or misconfigured, and outdoor units may be installed where they cannot drain properly in freezing weather. Ask whether the equipment has been tested in heating mode, how auxiliary heat is staged, and whether the system can hold temperature through a multi-day freeze rather than only a cold morning.
In a cooling-dominated climate the envelope decisions — window shading, attic insulation, radiant barriers, air sealing at the ceiling plane — change the load the equipment has to meet, and they are usually cheaper than capacity. The best moment to address them is when the system is being replaced anyway, because the attic is open and the ducts are accessible. Ask whether any of that work is included, whether the sizing assumed it would happen, and what the expected effect on the load is.
The season starts early and runs late, so the annual service has to happen before it, not after the first failure. Coil cleaning, a filter that is actually changed, a condensate line that drains and correct charge are the ordinary items, and a system that skips them loses capacity precisely when it is needed most. Ask what the visit covers and whether the condensate line is included, because that is the item that damages houses when it clogs.
- Is there a room-by-room load calculation that includes latent load? - Can the proposed equipment run at reduced capacity for longer periods? - Will the ducts, plenum and boots be sealed or tested? - Has the heating side been tested, including defrost and auxiliary heat? - Where do the outdoor units sit, and can they drain in freezing weather? - Is any envelope work included, and did the sizing assume it?
No prices, sizes or efficiency figures are quoted here. Refrigerant rules, code requirements and equipment ratings change, and the applicable version should be confirmed from the manufacturer's literature and the local authority.
The 2024 ACS 5-year estimates describe about 2.66 million residents in 967,488 households and 1,057,823 housing units, with 63.3% owner-occupied and 66.1% single-family detached. About 32.7% of units predate 1980. At the reference station the annual mean is 69.6°F, with July at 84.8°F and January at 52.2°F; annual precipitation is 32.4 inches.
| Indicator | Value | Source |
|---|---|---|
| January mean temperature | 52.2°F | NOAA NCEI |
| July mean temperature | 84.8°F | NOAA NCEI |
| Annual precipitation | 32.4 in. | NOAA NCEI |
| Metro population | 2,662,733 | U.S. Census Bureau |
| Owner-occupied share | 63.3% | U.S. Census Bureau |
| Housing units built before 1980 | 32.7% | U.S. Census Bureau |
Station normals are historical averages for one location, not a forecast. An average January near 52°F says nothing about the occasional hard freeze that decides whether a heating system actually works.
Reviewed on 2026-11-18.