Memphis, TN-MS-AR · metro guide
Solar Panels in Memphis: Heat Derating, Storm Risk, and an Older Roof Stock
The sun is adequate. What costs production here is heat, and what costs money is a roof near the end of its life.
Metro snapshot
Memphis in numbers
Sources named below each block
- Population
- 1.3M
- Households
- 523K
- Housing units
- 580K
- People / household
- 2.57
- population ÷ households
Owner-occupied homes 61%
The rest are rented. Owners are the ones who commission most exterior work.
Single-family detached 70%
Detached houses carry their own roof, gutters and exterior walls.
Built before 1980 46%
Older housing stock shapes what fails first: gutters, flashing, pipe material.
Season
The year in Memphis
- Precipitation
- 54.9 in
- Snowfall
- 2.7 in
Average temperature by month, °F — the shape of the year is what decides when exterior work gets done.
Precipitation by month, inches.
Snowfall by month, inches.
| Month | Average temperature (°F) | Precipitation (in) | Snowfall (in) |
|---|---|---|---|
| January | 42.1°F | 4.14 in | 0.9 in |
| February | 46.1°F | 4.55 in | 1.0 in |
| March | 54.2°F | 5.74 in | 0.5 in |
| April | 63.2°F | 5.87 in | 0.0 in |
| May | 72.1°F | 5.27 in | 0.0 in |
| June | 79.9°F | 3.99 in | 0.0 in |
| July | 82.8°F | 4.82 in | 0.0 in |
| August | 82.1°F | 3.37 in | 0.0 in |
| September | 76.0°F | 3.03 in | 0.0 in |
| October | 64.6°F | 3.98 in | 0.0 in |
| November | 52.7°F | 4.69 in | 0.1 in |
| December | 44.8°F | 5.49 in | 0.2 in |
NOAA 1991–2020 climate normals, station MEMPHIS INTL AP, TN US (USW00013893). Station observations, not a metro-wide average — a metro that spans a mountain range can differ by more than this record shows.
Population, households and housing shares: U.S. Census Bureau, American Community Survey 2024 5-year estimates, metropolitan statistical area.

Memphis sits in a band where solar works well but not spectacularly, and the limiting factor is not sunshine hours. It is heat. A photovoltaic module loses output as its cells warm, and cells on a roof in a hot, humid summer run far above air temperature, so a production estimate that uses standard test conditions without adjusting for local temperature will overstate the result. Add a housing stock where 46.1% of units predate 1980 and a storm season that brings hail and high wind, and the questions worth asking a Memphis installer are about derating, roof condition and wind rating rather than about how sunny it is.
Hot, humid air costs you output
The temperature coefficient on a module is published and it is not a rounding error in a climate this warm. Heat also interacts with mounting: panels flush against a hot shingle surface run hotter than panels with an air gap and airflow behind them. Ask what cell temperature the model assumed, whether the design allows for airflow, and how the seasonal production profile looks. A quote built from a generic sun-hours figure will not reflect the difference between March and August here.
Hail, wind, and the storm season
Severe thunderstorms bring hail and strong straight-line wind, and both put demands on the mounting and on the modules. Ask what the hail impact rating of the equipment is, what wind speed the mounting is engineered for, and how the roof penetrations are flashed. This is also where roof age becomes a financial issue: an array installed on a covering that is nearing replacement will have to be removed and reinstalled after the next storm claim, and that cost falls on the homeowner rather than the insurer in most cases.
Roof condition decides the project
Nearly half the housing here was built before 1980, which means a large number of the roofs being quoted are original or first-generation replacements. Before any panel layout is discussed, ask how old the covering is, what the remaining service life is judged to be, and whether the installer will put that judgement in writing. On older houses, the deck and the attic ventilation deserve attention at the same time, because a hot attic shortens the life of the shingles above it, with or without solar.
Tree cover is the quiet production killer
Older neighborhoods here have mature trees, and a roof plane that looks clear in winter can be shaded for hours in summer when the canopy is full. A shade study should cover the seasons, not one afternoon. Ask which hours of the year were modelled, whether the design uses string inverters or per-panel electronics so that a shaded section does not drag the rest, and what the plan is if a tree is removed or a neighbor builds upward.
The billing rules are part of the economics
How exported energy is credited, what fixed charges remain, and how accumulated credits are treated at the end of a period all change the payback more than a small difference in panel efficiency. Ask who files the interconnection request with the local utility, what the expected review window is, and what the current credit structure is in writing. Confirm it with the utility rather than relying on the installer's summary, since these terms have been revised in many states in recent years.
What to ask a Memphis installer
Where this page stops
No prices, incentives or production figures are published here, because none can be produced honestly without a site assessment. Roof condition and structural capacity require inspection, and financial and regulatory questions belong to a qualified adviser and the utility.
Memphis metro context
The 2024 ACS 5-year estimates count about 1.34 million residents in 522,879 households across 580,185 housing units, with 60.5% owner-occupied and 69.9% single-family detached — a high detached share, which means many households control a roof plane suitable for an array. About 46.1% of units were built before 1980. A climate station is not reported for this metro in the site dataset, so no temperature or precipitation normals appear on this page.
Memphis housing and ownership indicators
| Indicator | Value | Source |
|---|---|---|
| Single-family detached share | 69.9% | U.S. Census Bureau |
| Owner-occupied share | 60.5% | U.S. Census Bureau |
| Housing units built before 1980 | 46.1% | U.S. Census Bureau |
| Housing units | 580,185 | U.S. Census Bureau |
| Metro households | 522,879 | U.S. Census Bureau |
| Metro population | 1,341,924 | U.S. Census Bureau |
No climate normals are shown because no station record is held for this metro in the site dataset. Irradiance and cell temperature have to be modelled for the specific roof.
Frequently Asked Questions
Is Memphis a good place for solar?
It is workable, and most of the loss compared with a desert installation comes from heat rather than from lack of sun. Whether it makes sense for a particular house depends on roof condition, shade, orientation and the current utility credit structure.
How much does heat reduce output?
That depends on the module's temperature coefficient and how hot the cells get in service, which in turn depends on the mounting and the roof surface. It is a real and predictable effect, so ask whether the production estimate models it rather than assuming it away.
Will hail damage the panels?
Equipment is rated for hail impact, and the rating matters in a metro that sees severe storms. Ask for the rating and how the mounting and penetrations are detailed, and confirm that the array is included in the homeowner's insurance.
What if my roof needs replacing soon?
Do the roof first. Removing and reinstalling an array is a real cost and is usually not covered by a roofing claim, so paying for it twice is the avoidable expense in these projects.
Do trees really matter that much?
In older neighborhoods they can decide the project. A shaded section of a string can pull down the whole circuit, which is why a seasonal shade study and per-panel electronics are worth discussing.
How will I know the system is performing?
Monitoring at the inverter or per panel, compared month by month against the modelled estimate. Ask what is monitored, how underperformance is detected, and who is responsible for investigating it.
Sources and review date
- American Community Survey 2024 5-year estimates (CBSA tables) — U.S. Census Bureau, 2024 ACS 5-year estimates.
Reviewed on 2026-11-18.